Vein Detector-The Instrument of Modern Science

AHTINCAMK321SyringePump-1

Syringe Pump Model: AMK321

Syringe Pump AMK321

1. Clear & obvious screen information with big LCD; 

2. Easy syringe installation with "Jaw opening" Mechanism structure;

3. Suitable to all type syringe;

4. Automatically identify 5ml, 10ml, 20ml & 50/60ml syringes;

5. 8 grades adjustable jam-pressure; 

6. Stackable multi-channel syringe pump

Syringe Pump AMK321

 

         

1. Clear & obvious screen information with big LCD; 

2. Easy syringe installation with "Jaw opening" Mechanism structure;

3. Suitable to all type syringe;

4. Automatically identify 5ml, 10ml, 20ml & 50/60ml syringes;

5. 8 grades adjustable jam-pressure; 

6. Stackable multi-channel syringe pump

 

Specification:

Safety Control

Mufti-supervision   technology, self-test   when turn-on   and real-time self-test when infusing

Display

320*240 Dot-matrix LCD

Applicable Syringes

5ml, 10ml, 20ml, 30, 50ml, Auto-recognize

Flow Rate Range

1.5ml syringe 1ml/h~200ml/h    2.10ml   syringe 1ml/h~300ml/h

3.20ml syringe 1ml/h~400ml/h   4.30ml   syringe 1ml/h~600ml/h

5.50ml syringe 1ml/h~1200ml/h

Flow Rate Accuracy

±2% (Mechanical Accuracy ±1%)

Limited Volume Range

0.1~9999.9ml

Infused Volume Display

0.1~9999.9ml

Applicable Syringes Brand

Preset 15 Kinds, and user added

Purge Rate

1.5ml syringe   150ml/h              2.10ml   syringe 220ml/h

3.20ml syringe   330ml/h             4.30ml   syringe 540ml/h

5.50ml syringe 800ml/h

Bolus Flow Rate Range

1.5ml syringe 1ml/h~200ml/h    2.10ml   syringe 1ml/h~300ml/h

3.20ml syringe 1ml/h~400ml/h   4.30ml   syringe 1ml/h~600ml/h

5.50ml syringe 1ml/h~1200ml/h

KVO Flow Rate

1.0~5.0ml/h

Body Weight/Drug Mode Rate

10 Optional (ml/h, ml/min, mg/h, ug/h, mg/min, ug/min, mg/kg/h, mg/kg/min, ug/kg/h, ug/kg/min)

Occulusion Pressure

8 Level Sensitivity, 20~140KPa, Dynamic Pressure

Alarms

Syringe disloacated, Syringe handspike Err., Pre-alarm   of completed limited volume, Completed limited   volume, Near   empty, Empty, Occulusion, Bolus volume finished, Low   battery, Battery empty, Reminder alarm

Power Supply

AC 100~240V, 50/60Hz, Power consumption   ≤25VA

Internal Battery

Ni-MH, 12V, 800mAh(or Li, 11.1V, 1800mAh)

Battery Operation

3.0(or 7) Hours at 25ml/h

Classication

Class I, Internal power supply, CF   type, IPX4

Data Communication Interface

wireless (accessories)

Operating Conditions

Temperature +5℃~+40℃, Relative   humidity 20%~95%

Package Size

3200px(W)*2125px(H)*22(D)cm

Package Weight

3.5kg